20% off purchase of 3 or more products* | Learn More >>

Product listing: Propidium Iodide (PI)/RNase Staining Solution #4087 to SignalFire™ Elite ECL Reagent #12757

$124
100 ml
APPLICATIONS

Application Methods: Flow Cytometry, Immunofluorescence (Frozen), Immunofluorescence (Immunocytochemistry), Immunofluorescence (Paraffin)

$168
50 µg
Molecular Weight:540.73 g/mol
APPLICATIONS
REACTIVITY
All Species Expected

Application Methods: Immunofluorescence (Immunocytochemistry)

$64
2 x 25 ml
50 ml
$211
10 x 25 ml
250 ml
STOP Solution is a proprietary solution used to terminate the peroxidase/TMB reaction for ELISA applications. The TMB substrate reacts with immobilized horseradish peroxidase (HRP) conjugated secondary antibodies to produce a blue solution. Color intensity is an indication of analyte level. After attaining the desired intensity, the reaction is terminated by addition of STOP Solution. Upon addition of STOP Solution the color turns from blue to yellow. Absorbance at 450 nm can be read immediately, and the reaction is stable for one hour.
REACTIVITY
All Species Expected
$58
50 ml
$191
250 ml
TMB Substrate used is ready to use for ELISA detection. Reaction between the substrate and immobilized horseradish peroxidase (HRP) conjugated secondary antibodies in the ELISA wells produces a blue colored solution. Color intensity and development time will vary depending on assay sensitivity and conditions. After reaching the desired color intensity, the reaction is terminated by addition of an acidic STOP solution which changes the solution color from blue to yellow. While the results will remain stable for one hour following termination, the plate should be analyzed promptly on a microwell reader at 450 nm. TMB is light sensitive and is therefore packaged in amber bottles to protect the solution from direct sunlight. Recommended storage temperature is 4ºC.
REACTIVITY
All Species Expected
$64
5 ml each
$205
25 ml each
LumiGLO®* chemiluminescent substrate is a luminol-based system designed for use with our Phototope®-HRP detection assays utilizing peroxidase-labeled antibodies immobilized on membranes. In the presence of hydrogen peroxide, horseradish peroxidase (HRP) converts luminol to an excited intermediate dianion. This dianion emits light on return to its ground state. Light emission is maximal immediately after exposure of the substrate to HRP and continues for 0.5-1 hour. Light can be captured on X-ray film, typically by exposure for a few seconds. Maximum sensitivity can be obtained by longer exposure. *Avoid repeated exposure to skin (see enclosed Material Safety Data Sheet or refer to our website for further information).
APPLICATIONS

Application Methods: Western Blotting

Background: Chemiluminescence systems have emerged as the best all-around method for western blot detection. They eliminate the hazards associated with radioactive materials and toxic chromogenic substrates. The speed and sensitivity of these methods are unequalled by traditional alternatives, and because results are generated on film, it is possible to record and store data permanently. Blots detected with chemiluminescent methods are easily stripped for subsequent reprobing with additional antibodies. HRP-conjugated secondary antibodies are utilized in conjunction with specific chemiluminescent substrates to generate the light signal. HRP conjugates have a very high turnover rate, yielding good sensitivity with short reaction times.

The BCA Protein Assay Kit can be used to measure the protein concentration of lysates or homogenates, in microplate format, prepared with the following buffers: Cell Lysis Buffer (10X) #9803, RIPA Buffer (10X) #9806, PathScan® Sandwich ELISA Lysis Buffer (1X) #7018. The dynamic range for this assay is 0.125 - 2 mg/mL. It is recommended that the BCA Compatibility Reagent be used to decrease interference from reducing agents, chelators, detergents, and other common ingredients found in most lysis buffers. Please see the attached protocol for additional details.
The Phototope-HRP Western Blot Detection System is designed for the chemiluminescent detection of proteins in standard Western blotting applications. Proteins and biotinylated molecular weight markers (provided) are separated by SDS-PAGE and transferred onto membrane. Following incubation with your primary anti-serum, horseradish peroxidase (HRP) linked secondary antibody and HRP-linked anti-biotin antibody are bound and then allowed to react with LumiGLO® reagent. The light emitted by destabilized LumiGLO® reagent is subsequently captured on X-ray film.

Background: Chemiluminescence systems have emerged as the best all-around method for western blot detection. They eliminate the hazards associated with radioactive materials and toxic chromogenic substrates. The speed and sensitivity of these methods are unequalled by traditional alternatives, and because results are generated on film, it is possible to record and store data permanently. Blots detected with chemiluminescent methods are easily stripped for subsequent reprobing with additional antibodies. HRP-conjugated secondary antibodies are utilized in conjunction with specific chemiluminescent substrates to generate the light signal. HRP conjugates have a very high turnover rate, yielding good sensitivity with short reaction times.

The Phototope-HRP Western Blot Detection System is designed for the chemiluminescent detection of proteins in standard Western blotting applications. Proteins and biotinylated molecular weight markers (provided) are separated by SDS-PAGE and transferred onto membrane. Following incubation with your primary anti-serum, horseradish peroxidase (HRP) linked secondary antibody and HRP-linked anti-biotin antibody are bound and then allowed to react with LumiGLO® reagent. The light emitted by destabilized LumiGLO® reagent is subsequently captured on X-ray film.

Background: Chemiluminescence systems have emerged as the best all-around method for western blot detection. They eliminate the hazards associated with radioactive materials and toxic chromogenic substrates. The speed and sensitivity of these methods are unequalled by traditional alternatives, and because results are generated on film, it is possible to record and store data permanently. Blots detected with chemiluminescent methods are easily stripped for subsequent reprobing with additional antibodies. HRP-conjugated secondary antibodies are utilized in conjunction with specific chemiluminescent substrates to generate the light signal. HRP conjugates have a very high turnover rate, yielding good sensitivity with short reaction times.

$30
25 ml each substrate
50 ml
$259
250 ml each substrate
500 ml
SignalFire™ ECL Reagent from Cell Signaling Technology (CST) is an enhanced chemiluminescent substrate capable of detecting picogram amounts of protein by western blot analysis. Compared to entry-substrates, SignalFire™ ECL Reagent boasts a more robust signal and extended duration of signal output. In the presence of hydrogen peroxide, horseradish peroxidase (HRP) converts luminol to an excited intermediate dianion. This dianion emits light on return to its ground state. Light emission is maximal immediately after exposure of the substrate to HRP and continues for 1 hour. Light can be captured on X-ray film, typically by exposure for a few seconds. Maximum sensitivity can be obtained with longer exposure.
APPLICATIONS

Application Methods: Western Blotting

Background: Chemiluminescence systems have emerged as the best all-around method for western blot detection. They eliminate the hazards associated with radioactive materials and toxic chromogenic substrates. The speed and sensitivity of these methods are unequalled by traditional alternatives, and because results are generated on film, it is possible to record and store data permanently. Blots detected with chemiluminescent methods are easily stripped for subsequent reprobing with additional antibodies. HRP-conjugated secondary antibodies are utilized in conjunction with specific chemiluminescent substrates to generate the light signal. HRP conjugates have a very high turnover rate, yielding good sensitivity with short reaction times.

$86
10 ml each substrate
20 ml
$390
50 ml each substrate
100 ml
SignalFire™ Elite ECL Reagent from Cell Signaling Technology (CST) is an ultra sensitive chemiluminescent substrate capable of detecting femtogram amounts of protein by western blot analysis. SignalFire™ Elite ECL Reagent is compatible with both film and digital imaging systems. The extremely intense signal output allows detection of very low abundance proteins, conservation of reagents, and short exposure times.SignalFire™ Elite ECL Reagent requires approximately ten-fold less Anti-rabbit IgG, HRP-linked Antibody #7074 or Anti-mouse IgG, HRP-linked Antibody #7076 than traditional ECL reagents. Limiting the amount of HRP exposed to the membrane prevents high background, oversaturation of the target protein signal, or false negative results. Other HRP-conjugated antibodies, including HRP-conjugated primary and anti-biotin-HRP antibodies, should be diluted similarly. Dilution of secondary antibody from alternative vendors may need to be optimized. Titration of lysate and primary antibody concentration is recommended to achieve optimal signal-to-noise ratio.
APPLICATIONS

Application Methods: Western Blotting

Background: Chemiluminescence systems have emerged as the best all-around method for western blot detection. They eliminate the hazards associated with radioactive materials and toxic chromogenic substrates. The speed and sensitivity of these methods are unequalled by traditional alternatives, and because results are generated on film, it is possible to record and store data permanently. Blots detected with chemiluminescent methods are easily stripped for subsequent reprobing with additional antibodies. HRP-conjugated secondary antibodies are utilized in conjunction with specific chemiluminescent substrates to generate the light signal. HRP conjugates have a very high turnover rate, yielding good sensitivity with short reaction times.