Revision 1

#63387Store at -20C

1 Kit

(9 x 20 microliters)

Cell Signaling Technology

Orders: 877-616-CELL (2355) [email protected]

Support: 877-678-TECH (8324)

Web: [email protected] cellsignal.com

3 Trask LaneDanversMassachusetts01923USA
For Research Use Only. Not for Use in Diagnostic Procedures.
Product Includes Product # Quantity Mol. Wt Isotype/Source
COL1A1 (E8F4L) XP® Rabbit mAb 72026 20 µl 220 kDa Rabbit IgG
Tenascin C (E5J3B) Rabbit mAb 33352 20 µl 200, 240 kDa Rabbit IgG
Thrombospondin-1 (D7E5F) Rabbit mAb 37879 20 µl 170 kDa Rabbit IgG
Fibronectin/FN1 (E5H6X) Rabbit mAb 26836 20 µl 300 kDa Rabbit IgG
COL4A1 Antibody 50273 20 µl 200 kDa Rabbit 
SPARC (D10F10) Rabbit mAb 8725 20 µl 42 kDa Rabbit IgG
Periostin (E5F2S) Rabbit mAb 20302 20 µl 90 kDa Rabbit IgG
Anti-rabbit IgG, HRP-linked Antibody 7074 100 µl Goat 
COL3A1 (E8D7R) XP® Rabbit mAb 63034 20 µl 200 kDa Rabbit IgG
CYR61 (D4H5D) XP® Rabbit mAb 14479 20 µl 41 kDa Rabbit IgG

Please visit cellsignal.com for individual component applications, species cross-reactivity, dilutions, protocols, and additional product information.

Description

The Extracellular Matrix Dynamics Antibody Sampler Kit provides an economical means of detecting selected proteins associated with dynamic remodeling of the extracellular matrix. The kit includes enough antibodies to perform two western blot experiments with each primary antibody.

Storage

Supplied in 10 mM sodium HEPES (pH 7.5), 150 mM NaCl, 100 µg/mL BSA, 50% glycerol, and less than 0.02% sodium azide. Store at –20°C. Do not aliquot the antibodies.

Background

The extracellular matrix (ECM) is a three-dimensional macromolecular network composed of collagens, proteoglycans, glycosaminoglycans, elastin, fibronectin, laminins, along with many other proteins and glycoproteins. This network of macromolecules provides a dynamic microenvironment that supports cell and tissue function, and undergoes continuous remodeling during both normal development and disease (1). Remodeling of the ECM can alter the relative balance of macromolecules within distinct ECM subcompartments, with important functional consequences; for example, changes to the relative amounts of COL1A1 and COL3A1 in the interstitial ECM, or COL4A1 and laminins in the basement membrane, can influence cell-matrix interactions, and/or disrupt cellular signaling events (2). Fibronectin functions as a physical and functional bridge between many different ECM components, including collagens, growth factors, and cell surface integrins, and thus plays a critical role in facilitating ECM remodeling. Matricellular proteins (MCPs) are another important group of ECM proteins. MCPs can be categorized into 6 distinct subgroups: centralized coordination network (CCN), thrombospondin (THBS), secreted protein acidic and rich in cysteine (SPARC), tenascin (TN), small integrin-binding ligand N-linked glycoprotein (SIBLING), and γ-carboxyglutamate (Gla)-containing proteins. CCN1 (CYR61), SPARC, tenascin C, periostin, and thrombospondin-1 are among the most well-studied of this group. All are non-structural ECM proteins that interact with structural ECM proteins, in part to regulate the rigidity of the ECM. They also play important roles in matrix-cell communication by engaging with cell surface receptors and integrins to elicit intracellular responses. The dysregulation of MCP expression has been associated with the development of numerous disease states, including cancer and fibrosis (4,5).

  1. Bonnans, C. et al. (2014) Nat Rev Mol Cell Biol 15, 786-801.
  2. Theocharis, A.D. et al. (2019) FEBS J 286, 2830-2869.
  3. Zollinger, A.J. and Smith, M.L. (2017) Matrix Biol 60-61, 27-37.
  4. Gerarduzzi, C. et al. (2020) Cancer Res 80, 2705-2717.
  5. Feng, D. and Gerarduzzi, C. (2020) Int J Mol Sci 21, 4776. doi: 10.3390/ijms21134776.

Background References

    Trademarks and Patents

    Cell Signaling Technology is a trademark of Cell Signaling Technology, Inc.
    XP is a registered trademark of Cell Signaling Technology, Inc.
    All other trademarks are the property of their respective owners. Visit cellsignal.com/trademarks for more information.

    Limited Uses

    Except as otherwise expressly agreed in a writing signed by a legally authorized representative of CST, the following terms apply to Products provided by CST, its affiliates or its distributors. Any Customer's terms and conditions that are in addition to, or different from, those contained herein, unless separately accepted in writing by a legally authorized representative of CST, are rejected and are of no force or effect.

    Products are labeled with For Research Use Only or a similar labeling statement and have not been approved, cleared, or licensed by the FDA or other regulatory foreign or domestic entity, for any purpose. Customer shall not use any Product for any diagnostic or therapeutic purpose, or otherwise in any manner that conflicts with its labeling statement. Products sold or licensed by CST are provided for Customer as the end-user and solely for research and development uses. Any use of Product for diagnostic, prophylactic or therapeutic purposes, or any purchase of Product for resale (alone or as a component) or other commercial purpose, requires a separate license from CST. Customer shall (a) not sell, license, loan, donate or otherwise transfer or make available any Product to any third party, whether alone or in combination with other materials, or use the Products to manufacture any commercial products, (b) not copy, modify, reverse engineer, decompile, disassemble or otherwise attempt to discover the underlying structure or technology of the Products, or use the Products for the purpose of developing any products or services that would compete with CST products or services, (c) not alter or remove from the Products any trademarks, trade names, logos, patent or copyright notices or markings, (d) use the Products solely in accordance with CST Product Terms of Sale and any applicable documentation, and (e) comply with any license, terms of service or similar agreement with respect to any third party products or services used by Customer in connection with the Products.

    Revision 1
    #63387

    Extracellular Matrix Dynamics Antibody Sampler Kit

    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 1 Expand Image
    Western blot analysis of extracts from various cell lines using CYR61 (D4H5D) XP® Rabbit mAb (upper) and β-Actin (D6A8) Rabbit mAb #8457 (lower). As expected, MCF7 cells are negative for CYR61 expression.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 2 Expand Image
    Western blot analysis of extracts from Hs 578T and AN3-CA cells using Periostin (E5F2S) Rabbit mAb (upper) or GAPDH (D16H11) XP® Rabbit mAb #5174 (lower). Negative expression of periostin protein in AN3-CA cells is consistent with the predicted expression pattern.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 3 Expand Image
    Immunoprecipitation of periostin protein from Hs 578T cell extracts. Lane 1 is 10% input, lane 2 is Rabbit (DA1E) mAb IgG XP® Isotype Control #3900, and lane 3 is Periostin (E5F2S) Rabbit mAb. Western blot analysis was performed using Periostin (E5F2S) Rabbit mAb. Anti-rabbit IgG, HRP-linked Antibody #7074 was used as the secondary antibody.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 4 Expand Image
    Western blot analysis of extracts from various cell lines using Periostin (E5F2S) Rabbit mAb (upper) or GAPDH (D16H11) XP® Rabbit mAb #5174 (lower). Negative expression of periostin protein in SW620 cells is consistent with the predicted expression pattern.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 5 Expand Image
    Immunohistochemical analysis of paraffin-embedded human prostate adenocarcinoma using Periostin (E5F2S) Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 6 Expand Image
    Western blot analysis of extracts from various cell lines using Fibronectin/FN1 (E5H6X) Rabbit mAb (upper) and β-Actin (D6A8) Rabbit mAb #8457 (lower). The absence of Fibronectin/FN1 expression in PANC-1 cell extracts is consistent with molecular and proteomic expression profiling data, confirming specificity of the antibody.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 7 Expand Image
    Western blot analysis of extracts from RH-30 and IGROV-1 cells using Tenascin C (E5J3B) Rabbit mAb (upper) and β-Actin (D6A8) Rabbit mAb #8457 (lower). The differential in Tenascin C expression between RH-30 and IGROV-1 cells is consistent with their reported molecular expression profiles (CCLE, portals.broadinstitute.org), confirming specificity of the antibody for Tenascin C.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 8 Expand Image
    Western blot analysis of extracts from various cell lines using Thrombospondin-1 (D7E5F) Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 9 Expand Image
    Western blot analysis of extracts from various cell lines using COL4A1 Antibody (upper) and β-Actin (D6A8) Rabbit mAb #8457 (lower). The absence of COL4A1 expression in HCT 116 cell extracts is consistent with molecular and proteomic expression profiling data, confirming specificity of the antibody.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 10 Expand Image
    Western blot analysis of extracts from RD and ACHN cells using COL3A1 (E8D7R) XP® Rabbit mAb (upper) and β-Actin (D6A8) Rabbit mAb #8457 (lower). Differential expression of COL3A1 in RD and ACHN cell lines is consistent with molecular and proteomic expression profiling data, confirming specificity of the antibody for COL3A1.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 11 Expand Image
    Immunohistochemical analysis of paraffin-embedded human prostate adenocarcinoma using COL3A1 (E8D7R) XP® Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 12 Expand Image
    After the primary antibody is bound to the target protein, a complex with HRP-linked secondary antibody is formed. The LumiGLO® is added and emits light during enzyme catalyzed decomposition.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 13 Expand Image
    Western blot analysis of extracts from various cell lines using COL1A1 (E8F4L) XP® Rabbit mAb (upper) and GAPDH (D16H11) XP® Rabbit mAb #5174 (lower).
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 14 Expand Image
    Western blot analysis of culture medium, from SPARC-secreting PYS-2 cells, using SPARC (D10F10) Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 15 Expand Image
    Confocal immunofluorescent analysis of Saos-2 cells, untreated (left) or treated with Brefeldin A #9972 (10 μg/ml, overnight; center), and untreated MCF7 cells (right), using CYR61 (D4H5D) XP® Rabbit mAb (green). Actin filaments were labeled with DyLight 554 Phalloidin #13054 (red). Blue pseudocolor = DRAQ5® #4804 (fluorescent DNA dye).
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 16 Expand Image
    Immunohistochemical analysis of paraffin-embedded human esophageal adenocarcinoma using Periostin (E5F2S) Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 17 Expand Image
    Immunoprecipitation of Fibronectin/FN1 protein from Hep G2 cell extracts. Lane 1 is 10% input, lane 2 is Rabbit (DA1E) mAb IgG XP® Isotype Control #3900, and lane 3 is Fibronectin/FN1 (E5H6X) Rabbit mAb. Western blot analysis was performed using Fibronectin/FN1 (E5H6X) Rabbit mAb. Anti-rabbit IgG, HRP-linked Antibody #7074 was used as a secondary antibody.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 18 Expand Image
    Immunoprecipitation of Tenascin C protein from U-87 MG cell extracts. Lane 1 is 10% input, lane 2 is Rabbit (DA1E) mAb IgG XP® Isotype Control #3900, and lane 3 is Tenascin C (E5J3B) Rabbit mAb. Western blot analysis was performed using Tenascin C (E5J3B) Rabbit mAb. Mouse Anti-rabbit IgG (Conformation Specific) (L27A9) mAb (HRP Conjugate) #5127 was used as the secondary antibody.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 19 Expand Image
    Immunoprecipitation of thrombospondin-1 protein from ACHN cell extracts. Lane 1 is 10% input, lane 2 is Rabbit (DA1E) mAb IgG XP® Isotype Control #3900, and lane 3 is Thrombospondin-1 (D7E5F) Rabbit mAb. Western blot analysis was performed using Thrombospondin-1 (D7E5F) Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 20 Expand Image
    Immunohistochemical analysis of paraffin-embedded human gastrointestinal stromal tumor using COL3A1 (E8D7R) XP® Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 21 Expand Image
    Immunohistochemical analysis of paraffin-embedded human endometrioid adenocarcinoma using COL1A1 (E8F4L) XP® Rabbit mAb performed on the Leica® BOND Rx. 
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 22 Expand Image
    Immunohistochemical analysis of paraffin-embedded human colon carcinoma using SPARC (D10F10) Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 23 Expand Image
    Flow cytometric analysis of 293T cells (blue) and PANC-1 cells (green) using CYR61 (D4H5D) XP® Rabbit mAb (solid lines) or a concentration-matched Rabbit (DA1E) mAb IgG XP® Isotype Control #3900 (dashed lines). Anti-rabbit IgG (H+L), F(ab')2 Fragment (Alexa Fluor® 488 Conjugate) #4412 was used as a secondary antibody.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 24 Expand Image
    Immunohistochemical analysis of paraffin-embedded human lung adenocarcinoma using Periostin (E5F2S) Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 25 Expand Image
    Immunohistochemical analysis of paraffin-embedded human neuroendocrine carcinoma of the lung using Fibronectin/FN1 (E5H6X) Rabbit mAb performed on the Leica® BOND Rx.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 26 Expand Image
    Confocal immunofluorescent analysis of RH-30 cells (left, high-expressing) or HCT 116 cells (right, low-expressing) using Tenascin C (E5J3B) Rabbit mAb (green). Actin filaments were labeled with DyLight 554 Phalloidin #13054 (red). Sections were mounted in ProLong® Gold Antifade Reagent with DAPI #8961 (blue).
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 27 Expand Image
    Immunohistochemical analysis of paraffin-embedded human lung sarcoma using COL3A1 (E8D7R) XP® Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 28 Expand Image
    Immunohistochemical analysis of paraffin-embedded human prostate carcinoma using COL1A1 (E8F4L) XP® Rabbit mAb performed on the Leica® BOND Rx. 
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 29 Expand Image
    Immunohistochemical analysis of paraffin-embedded human lung carcinoma using SPARC (D10F10) Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 30 Expand Image
    Immunohistochemical analysis of paraffin-embedded human renal cell carcinoma using Periostin (E5F2S) Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 31 Expand Image
    Immunohistochemical analysis of paraffin-embedded Hep G2 cell pellet (left, positive) or PANC-1 cell pellet (right, negative) using Fibronectin/FN1 (E5H6X) Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 32 Expand Image
    Immunohistochemical analysis of paraffin-embedded human large cell neuroendocrine lung carcinoma using COL3A1 (E8D7R) XP® Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 33 Expand Image
    Immunohistochemical analysis of paraffin-embedded human prostate carcinoma using COL1A1 (E8F4L) XP® Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 34 Expand Image
    Immunohistochemical analysis of paraffin-embedded human colon adenocarcinoma using Periostin (E5F2S) Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 35 Expand Image
    Immunohistochemical analysis of paraffin-embedded human colon adenocarcinoma using Fibronectin/FN1 (E5H6X) Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 36 Expand Image
    Immunohistochemical analysis of paraffin-embedded human urothelial carcinoma using COL3A1 (E8D7R) XP® Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 37 Expand Image
    Immunohistochemical analysis of paraffin-embedded normal human kidney using COL1A1 (E8F4L) XP® Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 38 Expand Image
    Immunohistochemical analysis of paraffin-embedded 293T cell pellet, untransfected (left) or periostin-transfected (right), using Periostin (E5F2S) Rabbit mAb. 
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 39 Expand Image
    Immunohistochemical analysis of paraffin-embedded human ductal breast carcinoma using Fibronectin/FN1 (E5H6X) Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 40 Expand Image
    Immunohistochemical analysis of paraffin-embedded human colon adenocarcinoma using COL3A1 (E8D7R) XP® Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 41 Expand Image
    Immunohistochemical analysis of paraffin-embedded human esophageal adenocarcinoma using COL1A1 (E8F4L) XP® Rabbit mAb (left) compared to concentration-matched Rabbit (DA1E) mAb IgG XP® Isotype Control #3900 (right).
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 42 Expand Image
    Immunohistochemical analysis of paraffin-embedded human breast carcinoma using Periostin (E5F2S) Rabbit mAb (left) compared to concentration-matched Rabbit (DA1E) mAb IgG XP® Isotype Control #3900 (right). 
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 43 Expand Image
    Immunohistochemical analysis of paraffin-embedded human adenoid cystic carcinoma of the trachea using Fibronectin/FN1 (E5H6X) Rabbit mAb (left) or Fibronectin Rabbit mAb (right). These two antibodies detect independent, unique epitopes on human Fibronectin/FN1 protein. The similar staining patterns obtained with both antibodies help to confirm the specificity of the staining.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 44 Expand Image
    Immunohistochemical analysis of paraffin-embedded normal human kidney using COL3A1 (E8D7R) XP® Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 45 Expand Image
    Immunohistochemical analysis of paraffin-embedded mouse liver using COL1A1 (E8F4L) XP® Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 46 Expand Image
    Immunohistochemical analysis of paraffin-embedded Hs 578T cell pellet (left, positive) or AN3-CA cell pellet (right, negative) using Periostin (E5F2S) Rabbit mAb. 
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 47 Expand Image
    Immunohistochemical analysis of paraffin-embedded human colon adenocarcinoma using Fibronectin/FN1 (E5H6X) Rabbit mAb (left) compared to concentration-matched Rabbit (DA1E) mAb IgG XP® Isotype Control #3900 (right).
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 48 Expand Image
    Immunohistochemical analysis of paraffin-embedded human endometrioid adenocarcinoma using COL3A1 (E8D7R) XP® Rabbit mAb (left) compared to concentration-matched Rabbit (DA1E) mAb IgG XP® Isotype Control #3900 (right).
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 49 Expand Image
    Immunohistochemical analysis of paraffin-embedded mouse lung using COL1A1 (E8F4L) XP® Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 50 Expand Image
    Immunohistochemical analysis of paraffin-embedded human lung adenocarcinoma using Fibronectin/FN1 (E5H6X) Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 51 Expand Image
    Immunohistochemical analysis of paraffin-embedded RD cell pellet (left, positive) or ACHN cell pellet (right, negative) using COL3A1 (E8D7R) XP® Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 52 Expand Image
    Immunohistochemical analysis of paraffin-embedded A20 syngeneic tumor using COL1A1 (E8F4L) XP® Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 53 Expand Image
    Immunohistochemical analysis of paraffin-embedded human B-cell non-Hodgkin lymphoma using Fibronectin/FN1 (E5H6X) Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 54 Expand Image
    Immunohistochemical analysis of paraffin-embedded GL261 syngeneic tumor using COL1A1 (E8F4L) XP® Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 55 Expand Image
    Confocal immunofluorescent analysis of U-118 MG cells (left, positive) and PANC-1 cells (right, negative) using Fibronectin/FN1 (E5H6X) Rabbit mAb (green). Actin filaments were labeled with DyLight 650 Phalloidin #12956 (red). Samples were mounted in ProLong® Gold Antifade Reagent with DAPI #8961 (blue).
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 56 Expand Image
    Immunohistochemical analysis of paraffin-embedded U-118 MG cell pellet (left, positive) or HT-29 cell pellet (right, negative) using COL1A1 (E8F4L) XP® Rabbit mAb.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 57 Expand Image
    Immunohistochemical analysis of paraffin-embedded human colon carcinoma (left), renal cell carcinoma (middle) or prostate carcinoma (right) using COL1A1 (E8F4L) XP® Rabbit mAb (top) or COL1A1 (E3E1X) Mouse mAb #66948 (bottom). These two antibodies detect independent, unique epitopes on human COL1A1. The similar staining patterns obtained with both antibodies help to confirm the specificity of the staining.
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 58 Expand Image
    Confocal immunofluorescent analysis of mouse spleen using COL1A1 (E8F4L) XP® Rabbit mAb (green). After blocking free secondary antibody binding sites with Rabbit (DA1E) mAb IgG XP® Isotype Control #3900, the tissue was then labeled using Non-phospho (Active) β-Catenin (Ser45) (D2U8Y) XP® Rabbit mAb (Alexa Fluor® 488 Conjugate) #70034 (cyan pseudocolor) and α-Smooth Muscle Actin (D4K9N) XP® Rabbit mAb (Alexa Fluor® 594 Conjugate) #36110 (red). Samples were mounted in ProLong® Gold Antifade Reagent with DAPI #8961 (blue).
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 59 Expand Image
    Confocal immunofluorescent analysis of mouse colon using COL1A1 (E8F4L) XP® Rabbit mAb (green). After blocking free secondary antibody binding sites with Rabbit (DA1E) mAb IgG XP® Isotype Control #3900, the tissue was then labeled using Non-phospho (Active) β-Catenin (Ser45) (D2U8Y) XP® Rabbit mAb (Alexa Fluor® 488 Conjugate) #70034 (cyan pseudocolor) and α-Smooth Muscle Actin (D4K9N) XP® Rabbit mAb (Alexa Fluor® 594 Conjugate) #36110 (red). Samples were mounted in ProLong® Gold Antifade Reagent with DAPI #8961 (blue).
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 60 Expand Image
    Confocal immunofluorescent analysis of mouse liver using COL1A1 (E8F4L) XP® Rabbit mAb (green). After blocking free secondary antibody binding sites with Rabbit (DA1E) mAb IgG XP® Isotype Control #3900, the tissue was then labeled using Non-phospho (Active) β-Catenin (Ser45) (D2U8Y) XP® Rabbit mAb (Alexa Fluor® 488 Conjugate) #70034 (cyan pseudocolor) and α-Smooth Muscle Actin (D4K9N) XP® Rabbit mAb (Alexa Fluor® 594 Conjugate) #36110 (red). Samples were mounted in ProLong® Gold Antifade Reagent with DAPI #8961 (blue).
    Extracellular Matrix Dynamics Antibody Sampler Kit: Image 61 Expand Image
    Confocal immunofluorescent analysis of U-118 MG cells (left, positive) and HT-29 cells (right, negative) using COL1A1 (E8F4L) XP® Rabbit mAb (green). Actin filaments were labeled with DyLight 554 Phalloidin #13054 (red). Samples were mounted in ProLong® Gold Antifade Reagent with DAPI #8961 (blue).