View >Collapse >

S-Trap Sample Preparation Protocol

Day 1: Digest Proteins to Peptides

Reagents not supplied and equipment required:

  1. Phosphate Buffered Saline (PBS-20X) (CST #9808)
  2. Protein Quantitation Colorimetric Assay Kit, such as BCA Protein Assay Kit (CST #7780)
  3. 1mM Hydrochloric acid (HCl)
  4. Centrifuges capable of handling 15mL tubes and 1.5mL tubes
  5. Vacuum concentrator (Speed-Vac)

A. Solutions and Reagents

    NOTE: The S-Trap Midi Spin Columns can support the digestion of 0.3 – 5 mg soluble protein. Approximately 1 mg is recommended for a PTMScan® HS experiment.

  1. 1X S-Trap SDS Solubilization Buffer: Mix 5 mL of S-Trap SDS Solubilization Buffer (2X) with 5 mL of DI water to make Solubilization Buffer 1X. Store at room temperature. Prior to each experiment, for each sample, take out 1 ml of 1X S-Trap SDS Solubilization Buffer and mix with 10 uL of Phosphatase Inhibitor Cocktail (100X).
  2. Dithiothreitol (DTT): Make 1.25 M stock: Resuspend one tube containing 192.8 mg with 1 mL DI water. Divide into 25 uL aliquots. Store at -20°C for up to three months. Thaw one aliquot for each experiment.
  3. Iodoacetamide solution: Make 100 mM stock. Weigh out 19 mg of iodoacetamide and cover the tube with foil to protect it from light. Dissolve the powder in DI water to a final volume of 1 mL immediately before use. The iodoacetamide solution should be prepared fresh prior to each experiment.

B. Preparation of Cell Lysate, Cultured Cells

  1. Grow approximately 1-4 x 107 cells for each experimental condition (enough cells to produce approximately 1-2 mg of soluble protein). The cell number corresponds to approximately one 150 mm culture dish (depending on the cell type).
  2. Wash adherent cells in cold PBS, then harvest by scraping in 500 uL of 1X S-Trap SDS Solubilization Buffer per plate. For suspension cells, collect the cells by centrifugation and wash the pellet with cold 1X PBS. Harvest the pellet with 500 uL of 1X S-Trap SDS Solubilization Buffer. Do not cool lysate on ice as this may cause precipitation of the SDS. The harvested cells can be frozen and stored at -80°C for several weeks or proceed to sonication. (SAFE STOP)
  3. Using a sonicator with a microtip, sonicate lysate at 5 W output with 3 bursts of 15 sec each. Cool on ice for 1 min between each burst. Clear the lysate by centrifugation at 10,000 x g for 15 min at room temperature and transfer the protein extract (supernatant) into a new tube. Store the cleared lysate at -80°C at this point or continue directly through the Protein Quant and Digestion steps. (SAFE STOP)

    NOTE: Lysate sonication fragments DNA and reduces sample viscosity. Ensure that the sonicator tip is submerged in the lysate. If the tip is not submerged properly, it may induce foaming and degradation of your sample.

    NOTE: Centrifugation is performed at room temperature to prevent SDS from precipitating out of solution.

C. Preparation of Tissue Lysates

  1. Select a fresh-frozen piece of tissue and place it in a 50 mL conical tube. Add approximately 2 mL of 1X S-Trap SDS Solubilization Buffer per 100 mg of wet tissue, or enough to submerge it completely.
  2. Lyse the tissue using a homogenizer. Wash the tool with DI water in between each sample. Keep the moving parts submerged in buffer to avoid excessive foaming.
  3. Using a sonicator with a microtip, sonicate lysate at 5 W output with 3 bursts of 15 sec each. Cool on ice for 1 min between each burst. Clear the lysate by centrifugation at 10,000 x g for 15 min at room temperature and transfer the protein extract (supernatant) into a new tube. Store the cleared lysate at -80°C at this point or continue directly through the Protein Quant and Digestion steps. (SAFE STOP)

    NOTE: Lysate sonication fragments DNA and reduces sample viscosity. Ensure that the sonicator tip is submerged in the lysate. If the tip is not submerged properly, it may induce foaming and degradation of your sample.

    NOTE: Centrifugation is performed at room temperature to prevent SDS from precipitating out of solution.

D. Protein Quantitation

  1. Measure soluble protein concentration using a colorimetric assay kit that is compatible with the SDS lysis buffer. The bicinchoninic acid (BCA) assay is recommended.
  2. Normalize all samples so that equal amounts of protein are prepared for each condition and replicate. Alternatively, design the experiment so that equal numbers of cells are prepared for each sample.

E. Reduction and Alkylation of Proteins

  1. Add 1/278 volume of 1.25 M DTT to the cleared cell supernatant to reach 4.5mM DTT final concentration (e.g. 1.8 µl of 1.25 M DTT for 500 uL of protein extract). Mix well, and place the tube into a 55ºC incubator for 30 min.
  2. Cool the solution on ice briefly until it has reached room temperature.
  3. Add 1/10 volume of iodoacetamide solution to the cleared cell supernatant, mix well, and incubate for 15 min at room temperature in the dark.

F. S-Trap Cleanup and Protease Digestion

  1. Add 1/10 sample volume of S-Trap Phosphoric Acid to the sample and mix well.
  2. Transfer the sample to a 15 mL tube and add 6.6x the sample volume (eg. 3.3 mL) of S-Trap Binding/Wash Buffer. Mix well. A cloudy protein colloid should form immediately. 
  3. IMPORTANT: The protein in the sample is insoluble in the S-Trap Binding/Wash Buffer. DO NOT CENTRIFUGE the sample or allow it to settle before loading onto the S-trap in the next step.

  4. Load the full volume of sample onto the S-Trap, ensuring all the cloudy precipitate is transferred. Centrifuge 2 min at 4000 x g at room temperature until all the solution has passed through. Discard the flow-through.
  5. NOTE: All centrifugation steps for S-Traps should be performed at room temperature and 4000 x g.

  6. Wash the S-Trap with 3 mL of S-Trap Binding/Wash Buffer and centrifuge 2 min. Discard the flow-through. Repeat 3 times for 4 washes total.
  7. Transfer S-Trap to clean collection tubes prior to digestion.
  8. Prepare 350 uL of trypsin working solution for each sample. Use trypsin at 1:10 (w/w) enzyme:substrate (eg. 100 ug trypsin for 1 mg sample).  Dilute 1 mg/mL trypsin stock up to 350uL total with S-Trap Elution Buffer #1 (TEAB) and verify that the pH is ~8. The volume of digestion solution can be increased to ~500uL if more trypsin stock is needed. 
  9. Add the 350 uL trypsin solution to each cartridge and cap the tubes LOOSELY so that the digestion solution can absorb into the cartridge without creating negative air pressure. The cartridges may be centrifuged briefly but transfer any liquid that passes through back to the top of the cartridge. Place them in an incubator or water bath overnight at 37°C.
  10. IMPORTANT: Do not shake the tubes. Set the tubes in a rack so they remain secure and straight upright and the enzyme solution will absorb evenly into the cartridge bed.

    IMPORTANT: Complete tryptic digestion is critical for maximum peptide recovery in the following elution steps. Cutting incubation time short or using less than the recommended amount of trypsin will reduce performance.

  11. The next day, add 500 uL of S-Trap Elution Buffer #1 (TEAB) to the S-Traps and centrifuge 1 min or until all solution passes through at 4000 x g. Keep the cartridge in the same collection tube for all three elution steps (see steps 9 & 10).
  12. Add 500 uL of S-Trap Elution Buffer #2 (TFA) to the S-Traps, centrifuge 1 min or until all the solution passes through, at 4000 x g.
  13. Add 500 uL of S-Trap Elution Buffer #3 (ACN/TFA) to the S-Traps, centrifuge 1 min.
  14. Verify that the combined elutions have a pH<3. Transfer the eluate (1.85 mL altogether) to a 2 mL microcentrifuge tube.
  15. NOTE: At this stage, the peptides are clean for LCMS if analysis of the unmodified proteome is desired. 1% of the total volume can be set aside for this purpose.

  16. Dry the peptide solution in a vacuum concentrator (Speed-Vac) set to ambient temperature overnight or until completely dry. The pellet should be visible at the end.
  17. NOTE: Peptide solutions may be frozen at -80°C for 1 hr or longer before placing in the speedvac; this will prevent full tubes from spilling when placed at an angle to dry. (SAFE STOP)

    NOTE: A standard lyophilization apparatus is also acceptable in place of a vacuum concentrator.

    NOTE: Dry, digested peptides are stable at -80°C for several months (seal the closed tube with parafilm for storage). (SAFE STOP)

posted August 2020

revised October 2020

Protocol Id: 2184

Product Description

The PTMScan® HS Immunoenrichment Companion Reagents Kit includes ten S-Trap columns and all the necessary reagents to prepare purified peptides ready for posttranslational modification enrichment. Cells or tissues from any species are supported. The kit includes supplies to prepare ten trypsin digestions of 1 mg each, which is sufficient for ten immunoenrichments with a PTMScan® HS Antibody Kit. The soluble protein content of cells and tissues vary, but 1 x 107 cells or 15-30 mg of wet tissue from mammalian sources should be sufficient. Clean peptides are ready for PTM enrichment with only one day of hands-on work and one day of hands-off drying time.

Background

Proteomics analyses of posttranslationally modified peptides rely on both high-quality enrichments and pre-enrichment sample preparation. Suspension Traps (S-Trap columns) are a convenient tool to combine protein digestion and peptide cleanup into a single procedure. The S-Trap column is a spin filter made out of quartz that can trap large particles, such as precipitated proteins, but has little to no affinity for smaller particles, such as peptides (1). Cells and tissues can be prepared in any lysis buffer of choice, but buffers containing SDS are reported to extract more protein per cell than other buffers and help to maximize the performance of S-Trap columns (2). Acidifying the cell lysate and mixing it with methanol causes the proteins to precipitate, so that they can be captured on the S-Trap column with a brief centrifugation step. Detergents, along with lipids and any other contaminants, are washed away with additional methanol. The captured proteins can then be digested with trypsin or any other appropriate enzyme. Digesting on a solid substrate such as the S-Trap column enhances the enzymatic efficiency, reducing missed cleavages in comparison to in-solution methods (3). The peptides elute easily into mass spectrometry-friendly solutions. Once dried, these purified peptides are ready to be enriched for any PTM of interest using techniques such as IMAC #20432 or PTMScan®. If desired, the peptides are also ready for direct mass spectrometry analysis without further cleanup.

The S-Trap column workflow is much faster and less laborious than in-solution digestion because it avoids a separate peptide purification procedure. Once protein extracts are collected, reduction and alkylation takes 45 minutes, loading and washing the S-Trap columns takes 15 minutes, and then the samples are allowed to digest overnight. Clean peptides are collected the next morning in less than 15 minutes. Drying in a vacuum concentrator (or lyophilizer) can be completed over the next night, so that enrichment can be completed on the third day of sample preparation.

Limited Uses

Except as otherwise expressly agreed in a writing signed by a legally authorized representative of CST, the following terms apply to Products provided by CST, its affiliates or its distributors. Any Customer's terms and conditions that are in addition to, or different from, those contained herein, unless separately accepted in writing by a legally authorized representative of CST, are rejected and are of no force or effect.

Products are labeled with For Research Use Only or a similar labeling statement and have not been approved, cleared, or licensed by the FDA or other regulatory foreign or domestic entity, for any purpose. Customer shall not use any Product for any diagnostic or therapeutic purpose, or otherwise in any manner that conflicts with its labeling statement. Products sold or licensed by CST are provided for Customer as the end-user and solely for research and development uses. Any use of Product for diagnostic, prophylactic or therapeutic purposes, or any purchase of Product for resale (alone or as a component) or other commercial purpose, requires a separate license from CST. Customer shall (a) not sell, license, loan, donate or otherwise transfer or make available any Product to any third party, whether alone or in combination with other materials, or use the Products to manufacture any commercial products, (b) not copy, modify, reverse engineer, decompile, disassemble or otherwise attempt to discover the underlying structure or technology of the Products, or use the Products for the purpose of developing any products or services that would compete with CST products or services, (c) not alter or remove from the Products any trademarks, trade names, logos, patent or copyright notices or markings, (d) use the Products solely in accordance with CST Product Terms of Sale and any applicable documentation, and (e) comply with any license, terms of service or similar agreement with respect to any third party products or services used by Customer in connection with the Products.

For Research Use Only. Not for Use in Diagnostic Procedures.
Cell Signaling Technology is a trademark of Cell Signaling Technology, Inc.
PTMScan is a registered trademark of Cell Signaling Technology, Inc.
All other trademarks are the property of their respective owners. Visit our Trademark Information page.