Revision 1

#46599

Store at -20C

CST Logo
Orders:

877-616-CELL (2355)

[email protected]

Support:

877-678-TECH (8324)

3 Trask Lane | Danvers | Massachusetts | 01923 | USA

For Research Use Only. Not for Use in Diagnostic Procedures.

Product Includes Product # Quantity Mol. Wt Isotype/Source
Tri-Methyl-Histone H3 (Lys36) (D5A7) Rabbit Monoclonal Antibody490920 µl17 kDaRabbit IgG
Di-Methyl-Histone H3 (Lys36) (C75H12) Rabbit Monoclonal Antibody290120 µl17 kDaRabbit IgG
Mono-Methyl-Histone H3 (Lys36) (D9J1D) Rabbit Monoclonal Antibody1411120 µl17 kDaRabbit IgG
Histone H3 (D1H2) Rabbit Monoclonal Antibody449920 µl17 kDaRabbit IgG
Anti-rabbit IgG, HRP-linked Antibody7074100 µlGoat

Please visit cellsignal.com for individual component applications, species cross-reactivity, dilutions, protocols, and additional product information.

Description

The Methyl-Histone H3 (Lys36) Antibody Sampler Kit provides an economical means of detecting levels of mono-, di-, and tri-methyl histone H3 Lys36 using methyl-specific and control histone H3 antibodies. The kit contains enough primary antibodies to perform at least two western blot experiments.

Storage

Supplied in 10 mM sodium HEPES (pH 7.5), 150 mM NaCl, 100 µg/ml BSA, 50% glycerol and less than 0.02% sodium azide. Store at –20°C. Do not aliquot the antibody.

Background

The nucleosome, made up of four core histone proteins (H2A, H2B, H3, and H4), is the primary building block of chromatin. Originally thought to function as a static scaffold for DNA packaging, histones have now been shown to be dynamic proteins, undergoing multiple types of post-translational modifications, including acetylation, phosphorylation, methylation, and ubiquitination (1). Histone methylation is a major determinant for the formation of active and inactive regions of the genome and is crucial for the proper programming of the genome during development (2,3). Arginine methylation of histones H3 (Arg2, 17, 26) and H4 (Arg3) promotes transcriptional activation and is mediated by a family of protein arginine methyltransferases (PRMTs), including the co-activators PRMT1 and CARM1 (PRMT4) (4). In contrast, a more diverse set of histone lysine methyltransferases has been identified, all but one of which contain a conserved catalytic SET domain originally identified in the Drosophila Su(var)3-9, Enhancer of zeste, and Trithorax proteins. Lysine methylation occurs primarily on histones H3 (Lys4, 9, 27, 36, 79) and H4 (Lys20) and has been implicated in both transcriptional activation and silencing (4). Methylation of these lysine residues coordinates the recruitment of chromatin modifying enzymes containing methyl-lysine binding modules such as chromodomains (HP1, PRC1), PHD fingers (BPTF, ING2), tudor domains (53BP1), and WD-40 domains (WDR5) (5-8). The discovery of histone demethylases, such as PADI4, LSD1, JMJD1, JMJD2, and JHDM1, has shown that methylation is a reversible epigenetic marker (9).

Methylation of histone H3 Lys36 is associated with transcriptionally active genes. Tri- and di-methyl-histone H3 Lys36 levels are high in the bodies of active genes, where these marks function to repress intragenic transcription initiation and regulate mRNA splicing. Mono-methyl-histone H3 Lys36 levels are high in the bodies of both active and inactive genes.

Trademarks and Patents

Cell Signaling Technology is a trademark of Cell Signaling Technology, Inc.

U.S. Patent No. 7,429,487, foreign equivalents, and child patents deriving therefrom.

All other trademarks are the property of their respective owners. Visit cellsignal.com/trademarks for more information.

Limited Uses

Except as otherwise expressly agreed in a writing signed by a legally authorized representative of CST, the following terms apply to Products provided by CST, its affiliates or its distributors. Any Customer's terms and conditions that are in addition to, or different from, those contained herein, unless separately accepted in writing by a legally authorized representative of CST, are rejected and are of no force or effect.

Products are labeled with For Research Use Only or a similar labeling statement and have not been approved, cleared, or licensed by the FDA or other regulatory foreign or domestic entity, for any purpose. Customer shall not use any Product for any diagnostic or therapeutic purpose, or otherwise in any manner that conflicts with its labeling statement. Products sold or licensed by CST are provided for Customer as the end-user and solely for research and development uses. Any use of Product for diagnostic, prophylactic or therapeutic purposes, or any purchase of Product for resale (alone or as a component) or other commercial purpose, requires a separate license from CST. Customer shall (a) not sell, license, loan, donate or otherwise transfer or make available any Product to any third party, whether alone or in combination with other materials, or use the Products to manufacture any commercial products, (b) not copy, modify, reverse engineer, decompile, disassemble or otherwise attempt to discover the underlying structure or technology of the Products, or use the Products for the purpose of developing any products or services that would compete with CST products or services, (c) not alter or remove from the Products any trademarks, trade names, logos, patent or copyright notices or markings, (d) use the Products solely in accordance with CST Product Terms of Sale and any applicable documentation, and (e) comply with any license, terms of service or similar agreement with respect to any third party products or services used by Customer in connection with the Products.

Orders: 877-616-CELL (2355) [email protected] Support: 877-678-TECH (8324) [email protected] Web: cellsignal.com
For Research Use Only. Not for Use in Diagnostic Procedures.

Revision 1

Cell Signaling Technology Logo
Western blot analysis of extracts from various cell lines using Mono-Methyl-Histone H3 (Lys36) (D9J1D) Rabbit mAb.
undefined Image 1: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
CUT&Tag was performed with HeLa cells and Mono-Methyl-Histone H3 (Lys36) (D9J1D) Rabbit mAb, using CUT&Tag Assay Kit #77552. DNA library was prepared using CUT&Tag Dual Index Primers and PCR Master Mix for Illumina Systems #47415. The figure shows binding across the WDR70 gene.
undefined Image 2: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
CUT&RUN was performed with HeLa cells and either Mono-Methyl-Histone H3 (Lys36) (D9J1D) Rabbit mAb or Di-Methyl-Histone H3 (Lys4) (C64G9) Rabbit mAb #9725, using CUT&RUN Assay Kit #86652. DNA libraries were prepared using DNA Library Prep Kit for Illumina Systems (ChIP-seq, CUT&RUN) #56795. The figure shows binding across HOXA11.
undefined Image 3: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Orders: 877-616-CELL (2355) [email protected] Support: 877-678-TECH (8324) [email protected] Web: cellsignal.com
For Research Use Only. Not for Use in Diagnostic Procedures.

Revision 1

Cell Signaling Technology Logo
Antibody specificity was determined by Western blotting. HeLa and NIH/3T3 cell extracts were probed with Di-Methyl Histone H3 (Lys36) (C75H12) Rabbit mAb alone (Panel A) or Di-Methyl-Histone H3 (Lys36) (C75H12) Rabbit mAb pre-adsorbed with 1.5 μM of various competitor peptides (Panels B-I). As shown, only the di-methyl-histone H3 (Lys36) peptide competed away binding of the antibody.
undefined Image 4: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Western blot analysis of extracts from various cell lines using Histone H3 (D1H2) XP® Rabbit mAb.
undefined Image 5: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Immunohistochemical analysis of paraffin-embedded human breast carcinoma using Histone H3 (D1H2) XP® Rabbit mAb.
undefined Image 6: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Orders: 877-616-CELL (2355) [email protected] Support: 877-678-TECH (8324) [email protected] Web: cellsignal.com
For Research Use Only. Not for Use in Diagnostic Procedures.

Revision 1

Cell Signaling Technology Logo
Western blot analysis of extracts from various cell lines using Tri-Methyl-Histone H3 (Lys36) (D5A7) XP® Rabbit mAb.
undefined Image 7: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
CUT&RUN was performed with HeLa cells and Tri-Methyl-Histone H3 (Lys36) (D5A7) XP® Rabbit mAb, using CUT&RUN Assay Kit #86652. DNA Library was prepared using DNA Library Prep Kit for Illumina (ChIP-seq, CUT&RUN) #56795. The figure shows binding across JTB, a known target gene of H3K36me3 (see additional figure containing CUT&RUN-qPCR data).
undefined Image 8: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Chromatin immunoprecipitations were performed with cross-linked chromatin from HeLa cells and Tri-Methyl-Histone H3 (Lys36) (D5A7) XP® Rabbit mAb, using SimpleChIP® Plus Enzymatic Chromatin IP Kit (Magnetic Beads) #9005. DNA Libraries were prepared using SimpleChIP® ChIP-seq DNA Library Prep Kit for Illumina® #56795. The figure shows binding across ACTG1/γ-Actin, a known target gene of H3K36me3 (see additional figure containing ChIP-qPCR data).
undefined Image 9: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Orders: 877-616-CELL (2355) [email protected] Support: 877-678-TECH (8324) [email protected] Web: cellsignal.com
For Research Use Only. Not for Use in Diagnostic Procedures.

Revision 1

Cell Signaling Technology Logo
Flow cytometric analysis of A498 cells (blue) and 786-O cells (green) using Tri-Methyl-Histone H3 (Lys36) (D5A7) XP® Rabbit mAb (solid lines) or a concentration-matched Rabbit (DA1E) mAb IgG XP® Isotype Control #3900 (dashed lines). Anti-rabbit IgG (H+L), F(ab')2 Fragment (Alexa Fluor® 488 Conjugate) #4412 was used as a secondary antibody.
undefined Image 10: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
After the primary antibody is bound to the target protein, a complex with HRP-linked secondary antibody is formed. The LumiGLO® is added and emits light during enzyme catalyzed decomposition.
undefined Image 11: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Antibody specificity was determined by western blotting. HeLa and NIH/3T3 cell extracts were probed with Mono-Methyl-Histone H3 (Lys36) (D9J1D) Rabbit mAb alone (A) or Mono-Methyl-Histone H3 (Lys36) (D9J1D) Rabbit mAb

pre-adsorbed with 1.5 μM of various competitor peptides (B-I). As shown, only the mono-methyl-histone H3 (Lys36)

peptide competed away binding of the antibody (C).

undefined Image 12: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Orders: 877-616-CELL (2355) [email protected] Support: 877-678-TECH (8324) [email protected] Web: cellsignal.com
For Research Use Only. Not for Use in Diagnostic Procedures.

Revision 1

Cell Signaling Technology Logo
CUT&Tag was performed with HeLa cells and Mono-Methyl-Histone H3 (Lys36) (D9J1D) Rabbit mAb, using CUT&Tag Assay Kit #77552. DNA library was prepared using CUT&Tag Dual Index Primers and PCR Master Mix for Illumina Systems #47415. The figures show binding across the WDR70 gene (upper), and the HOXA gene cluster (lower).
undefined Image 13: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
CUT&RUN was performed with HeLa cells and either Mono-Methyl-Histone H3 (Lys36) (D9J1D) Rabbit mAb or Di-Methyl-Histone H3 (Lys4) (C64G9) Rabbit mAb #9725, using CUT&RUN Assay Kit #86652. DNA libraries were prepared using DNA Library Prep Kit for Illumina Systems (ChIP-seq, CUT&RUN) #56795. The figures show binding across HOXA (upper) and HOXD (lower) gene clusters.
undefined Image 14: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Western blot analysis of extracts from various cell lines using Di-Methyl-Histone H3 (Lys36) (C75H12) Rabbit mAb.
undefined Image 15: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Orders: 877-616-CELL (2355) [email protected] Support: 877-678-TECH (8324) [email protected] Web: cellsignal.com
For Research Use Only. Not for Use in Diagnostic Procedures.

Revision 1

Cell Signaling Technology Logo
Immunohistochemical analysis of paraffin-embedded 4T1 syngeneic mammary tumor using Histone H3 (D1H2) XP® Rabbit mAb.
undefined Image 16: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Immunohistochemical analysis of paraffin-embedded human papillary carcinoma of the breast using Tri-Methyl-Histone H3(K36) (D5A7) XP(R) Rabbit mAb.
undefined Image 17: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
CUT&RUN was performed with HeLa cells and Tri-Methyl-Histone H3 (Lys36) (D5A7) XP® Rabbit mAb, using CUT&RUN Assay Kit #86652. DNA Library was prepared using DNA Library Prep Kit for Illumina (ChIP-seq, CUT&RUN) #56795. The figures show binding across ATCG1 gene (upper) and JTB (lower), a known target gene of H3K36me3 (see additional figure containing CUT&RUN-qPCR data).
undefined Image 18: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Orders: 877-616-CELL (2355) [email protected] Support: 877-678-TECH (8324) [email protected] Web: cellsignal.com
For Research Use Only. Not for Use in Diagnostic Procedures.

Revision 1

Cell Signaling Technology Logo
Chromatin immunoprecipitations were performed with cross-linked chromatin from HeLa cells and Tri-Methyl-Histone H3 (Lys36) (D5A7) XP® Rabbit mAb, using SimpleChIP® Plus Enzymatic Chromatin IP Kit (Magnetic Beads) #9005. DNA Libraries were prepared using SimpleChIP® ChIP-seq DNA Library Prep Kit for Illumina® #56795. The figure shows binding across chromosome 17 (upper) and ACTG1/γ-Actin (lower), a known target gene of H3K36me3 (see additional figure containing ChIP-qPCR data).
undefined Image 19: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Confocal immunofluorescent analysis of HeLa cells using Mono-Methyl-Histone H3 (Lys36) (D9J1D) Rabbit mAb (green) and β-Actin (8H10D10) Mouse mAb #3700 (red).
undefined Image 20: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
CUT&RUN was performed with HeLa cells and either Mono-Methyl-Histone H3 (Lys36) (D9J1D) Rabbit mAb or Rabbit (DA1E) mAb IgG XP® Isotype Control (CUT&RUN) #66362, using CUT&RUN Assay Kit #86652. The enriched DNA was quantified by real-time PCR using SimpleChIP® Human HoxA1 Intron 1 Primers #7707, SimpleChIP® Human HoxA2 Promoter Primers #5517, and SimpleChIP® Human α Satellite Repeat Primers #4486. The amount of immunoprecipitated DNA in each sample is represented as signal relative to the total amount of input chromatin, which is equivalent to one.
undefined Image 21: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Orders: 877-616-CELL (2355) [email protected] Support: 877-678-TECH (8324) [email protected] Web: cellsignal.com
For Research Use Only. Not for Use in Diagnostic Procedures.

Revision 1

Cell Signaling Technology Logo
Immunohistochemical analysis of paraffin-embedded human gastric carcinoma using Di-Methyl-Histone H3 (Lys36) (C75H12) Rabbit mAb in the presence of non-methyl peptide (left) or K36 di-methyl peptide (right).
undefined Image 22: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Confocal immunofluorescent analysis of HeLa cells using Histone H3 (D1H2) XP® Rabbit mAb (green) and β-Tubulin (9F3) Rabbit mAb (Alexa Fluor® 555 Conjugate) #2116 (red).
undefined Image 23: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Immunohistochemical analysis of paraffin-embedded LL/2 syngeneic tumor using Histone H3 (D1H2) XP® Rabbit mAb.
undefined Image 24: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Orders: 877-616-CELL (2355) [email protected] Support: 877-678-TECH (8324) [email protected] Web: cellsignal.com
For Research Use Only. Not for Use in Diagnostic Procedures.

Revision 1

Cell Signaling Technology Logo
Chromatin immunoprecipitations were performed with cross-linked chromatin from HeLa cells and either Tri-Methyl-Histone H3 (Lys36) (D5A7) XP® Rabbit mAb or Normal Rabbit IgG #2729 using SimpleChIP® Plus Enzymatic Chromatin IP Kit (Magnetic Beads) #9005. The enriched DNA was quantified by real-time PCR using SimpleChIP® Human γ-Actin Promoter Primers #5037, SimpleChIP® Human γ-Actin Intron 3 Primers #5047, SimpleChIP® Human GAPDH Promoter Primers #4471, and SimpleChIP® Human GAPDH Intron 2 Primers #4478. The amount of immunoprecipitated DNA in each sample is represented as signal relative to the total amount of input chromatin, which is equivalent to one.
undefined Image 25: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Immunohistochemical analysis of paraffin-embedded human colon carcinoma using Tri-Methyl-Histone H3(K36) (D5A7) XP(R) Rabbit mAb.
undefined Image 26: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
CUT&RUN was performed with HeLa cells and either Tri-Methyl-Histone H3 (Lys36) (D5A7) XP® Rabbit mAb or Rabbit (DA1E) mAb IgG XP® Isotype Control (CUT&RUN) #66362, using CUT&RUN Assay Kit #86652. The enriched DNA was quantified by real-time PCR using human JTB exon 1 and SimpleChIP® Human α Satellite Repeat Primers #4486. The amount of immunoprecipitated DNA in each sample is represented as signal relative to the total amount of input chromatin, which is equivalent to one.
undefined Image 27: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Orders: 877-616-CELL (2355) [email protected] Support: 877-678-TECH (8324) [email protected] Web: cellsignal.com
For Research Use Only. Not for Use in Diagnostic Procedures.

Revision 1

Cell Signaling Technology Logo
Flow cytometric analysis of HeLa cells using Mono-Methyl-Histone H3 (Lys36) (D9J1D) Rabbit mAb (solid line) compared to concentration-matched Rabbit (DA1E) mAb IgG XP® Isotype Control #3900 (dashed line). Anti-rabbit IgG (H+L), F(ab')2 Fragment (Alexa Fluor® 647 Conjugate) #4414 was used as a secondary antibody.
undefined Image 28: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Flow cytometric analysis of HeLa cells using Histone H3 (D1H2) XP® Rabbit mAb (solid line) or a concentration-matched Rabbit (DA1E) mAb IgG XP® Isotype Control #3900 (dashed line). Anti-rabbit IgG (H+L), F(ab')2 Fragment (Alexa Fluor® 488 Conjugate) #4412 was used as a secondary antibody.
undefined Image 29: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Immunohistochemical analysis of paraffin-embedded mouse brain using Histone H3 (D1H2) XP® Rabbit mAb.
undefined Image 30: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Orders: 877-616-CELL (2355) [email protected] Support: 877-678-TECH (8324) [email protected] Web: cellsignal.com
For Research Use Only. Not for Use in Diagnostic Procedures.

Revision 1

Cell Signaling Technology Logo
Immunohistochemical analysis of paraffin-embedded 786-O cell pellet (left, positive) or A498 cell pellet (right, negative) using Tri-Methyl-Histone H3(K36) (D5A7) XP(R) Rabbit mAb. Note that the A498 cell line harbors a SETD2 mutation.
undefined Image 31: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Chromatin immunoprecipitations were performed with cross-linked chromatin from HeLa cells and Mono-Methyl-Histone H3 (Lys36) (D9J1D) Rabbit mAb, using SimpleChIP® Plus Enzymatic Chromatin IP Kit (Magnetic Beads) #9005. DNA libraries were prepared using DNA Library Prep Kit for Illumina Systems (ChIP-seq, CUT&RUN) #56795. The figures show binding across WDR70 gene.
undefined Image 32: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Immunohistochemical analysis of paraffin-embedded rhesus monkey liver using Histone H3 (D1H2) XP® Rabbit mAb.
undefined Image 33: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Orders: 877-616-CELL (2355) [email protected] Support: 877-678-TECH (8324) [email protected] Web: cellsignal.com
For Research Use Only. Not for Use in Diagnostic Procedures.

Revision 1

Cell Signaling Technology Logo
Immunohistochemical analysis of paraffin-embedded human serous papillary carcinoma of the ovary using Tri-Methyl-Histone H3(K36) (D5A7) XP(R) Rabbit mAb in the presence of non-methyl peptide (left) or K36 tri-methyl peptide (right).
undefined Image 34: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Chromatin immunoprecipitations were performed with cross-linked chromatin from HeLa cells and Mono-Methyl-Histone H3 (Lys36) (D9J1D) Rabbit mAb, using SimpleChIP® Plus Enzymatic Chromatin IP Kit (Magnetic Beads) #9005. DNA libraries were prepared using DNA Library Prep Kit for Illumina Systems (ChIP-seq, CUT&RUN) #56795. The figures show binding across WDR70 gene (upper) and MYT1 (lower), a known target gene of H3K36me1 (see additional figure containing ChIP-qPCR data).
undefined Image 35: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Immunohistochemical analysis of paraffin-embedded human prostate carcinoma using Tri-Methyl-Histone H3(K36) (D5A7) XP(R) Rabbit mAb.
undefined Image 36: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Orders: 877-616-CELL (2355) [email protected] Support: 877-678-TECH (8324) [email protected] Web: cellsignal.com
For Research Use Only. Not for Use in Diagnostic Procedures.

Revision 1

Cell Signaling Technology Logo
Chromatin immunoprecipitations were performed with cross-linked chromatin from HeLa cells and either Mono-Methyl-Histone H3 (Lys36) (D9J1D) Rabbit mAb or Normal Rabbit IgG #2729 using SimpleChIP® Enzymatic Chromatin IP Kit (Magnetic Beads) #9003. The enriched DNA was quantified by real-time PCR using SimpleChIP® Human AFM Intron 1 Primers #5098, SimpleChIP® Human GAPDH Exon 1 Primers #5516, SimpleChIP® Human MyoD Exon 1 Primers #4490, and SimpleChIP® Human MYT-1 Exon 1 Primers #4493. The amount of immunoprecipitated DNA in each sample is represented as signal relative to the total amount of input chromatin, which is equivalent to one.
undefined Image 37: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Confocal immunofluorescent analysis of HeLa cells using Tri-Methyl-Histone H3 (Lys36) (D5A7) XP® Rabbit mAb (green) and COX IV (4D11-B3-E8) Mouse mAb #11967 (red).
undefined Image 38: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Flow cytometric analysis of HeLa cells using Di-Methyl-Histone H3 (Lys36) (C75H12) XP® Rabbit mAb (blue) compared to concentration-matched Rabbit (DA1E) mAb IgG XP® Isotype Control #3900 (red). Anti-rabbit IgG (H+L), F(ab')2 Fragment (Alexa Fluor® 488 Conjugate) #4412 was used as a secondary antibody.
undefined Image 39: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Orders: 877-616-CELL (2355) [email protected] Support: 877-678-TECH (8324) [email protected] Web: cellsignal.com
For Research Use Only. Not for Use in Diagnostic Procedures.

Revision 1

Cell Signaling Technology Logo
Confocal immunofluorescent analysis of HeLa cells using Di-Methyl-Histone H3 (Lys36) (C75H12) Rabbit mAb (green) and β-Actin (8H10D10) Mouse mAb #3700 (red).
undefined Image 40: Methyl-Histone H3 (Lys36) Antibody Sampler Kit
Orders: 877-616-CELL (2355) [email protected] Support: 877-678-TECH (8324) [email protected] Web: cellsignal.com
For Research Use Only. Not for Use in Diagnostic Procedures.