Figure 1. Target Map of the PathScan® Cancer Phenotype Antibody Array Kit (Chemiluminescent Readout) #14821.

Learn more about how we get our images

Figure 2. HeLa and A-431 cells (upper), and HCC827 and Calu-3 cells (lower) were grown to 90% confluency. Cell Lysates were prepared and analyzed using the PathScan® Cancer Phenotype Antibody Array Kit (Chemiluminescent Readout) #14821. Images were acquired by briefly exposing the slide to standard chemiluminescent film.

Learn more about how we get our images
Image
Product Includes Quantity Cap Color
Array Slides - Cancer Phenotype Array 1 Kit
16-Well Gasket 2 ea
Sealing Tape 2 sheets
Chemiluminescent Development Folder
20X Array Wash Buffer 15 ml White
Array Blocking Buffer 5 ml Red
Array Diluent Buffer 15 ml Blue
Detection Antibody Cocktail (10X)  - Cancer Phenotype Array 300 µl White
HRP-Linked Streptavidin (10X) 300 µl Clear
20X LumiGLO® Reagent and 20X Peroxide 7003 5 ml each Brown
PathScan® Sandwich ELISA Lysis Buffer (1X) 7018 30 ml Clear

Product Description

The PathScan® Cancer Phenotype Antibody Array Kit (Chemiluminescent Readout) uses glass slides as the planar surface and is based upon the sandwich immunoassay principle. The array kit allows for the simultaneous detection of 19 cancer cell associated proteins. Target-specific capture antibodies have been spotted in duplicate onto nitrocellulose-coated glass slides. Each kit contains two slides allowing for the interrogation of 32 different samples and the generation of 608 data points in a single experiment. Cell lysates are incubated on the slide followed by a biotinylated detection antibody cocktail. HRP-linked Streptavidin and LumiGLO® Reagent are then used to visualize the bound detection antibody by chemiluminescence. An image of the slide can be captured with either a digital imaging system or standard chemiluminescent film. The image can be analyzed visually or the spot intensities quantified using array analysis software.


Specificity / Sensitivity

PathScan® Cancer Phenotype Antibody Array Kit (Chemiluminescent Readout) detects the target proteins as specified on the Array Target Map. No substantial cross-reactivity has been observed between targets. This kit is optimized for cell lysates diluted to a total protein concentration between 0.2 and 1 mg/ml (see kit protocol). All sandwich assays have been validated for human derived samples. This kit may also detect homologous proteins from other species.


Species Reactivity: Human

Despite shared hallmarks and common overarching principles, cancers are heterogeneous in nature. Widely used tumor derived cell lines often exhibit both genomic and proteomic differences relative to one another. Factors contributing to these differences include gradual accumulation of genetic lesions within cell lines, transcriptional networks and epigenetic marks remaining from the original tissue, and various adaptations to in vitro culture conditions. Cell lines may differ considerably in the architectural details of basic machineries, the wiring of signal transduction circuitry, and the set points of metabolic pathways. As a result, heterogeneous phenotypes within cell lines will manifest as differences in fundamental cellular functions and a range of behaviors under experimental conditions.

The cell surface represents a compartment where a high level of heterogeneity is displayed. Cancer cells can use the wide array of cell surface proteins to sense, attract, and respond to survival or growth factors in order to promote cancer cell proliferation and growth. Certain cell surface molecules can shield cancer cells from the immune response, help to procure nutrients and create more favorable conditions, and provide a means for the spread and colonization of the cancer cells to other tissues. The presence (or absence) of specific cellular proteins can be regarded as a characteristic phenotypic trait that allows for the classification of cancer cell type and may help predict cellular response to specific experimental conditions both in vitro and in vivo.

Understanding and modeling tumor cell behavior, sensitivity and resistance to various drugs, identification of oncogene dependencies and network vulnerabilities requires a systems-level measurement of multiple parameters. Therefore, it is important to simultaneously survey both the cell surface as well as key molecules that serve as indicators for cell cycle progression, epithelial to mesenchymal transition, and activation of the hypoxic response program.


1.  Scheel, C. and Weinberg, R.A. (2012) Semin Cancer Biol 22, 396-403.

2.  Hale, J.S. et al. (2012) Cell Adh Migr 6, 346-55.

3.  Varga, J. et al. (2014) FEBS Lett 588, 2422-7.

4.  Zöller, M. (2011) Nat Rev Cancer 11, 254-67.

5.  van Roy, F. (2014) Nat Rev Cancer 14, 121-34.

6.  Schnell, U. et al. (2013) Biochim Biophys Acta 1828, 1989-2001.

7.  Kufe, D.W. (2013) Oncogene 32, 1073-81.


Entrez-Gene Id 960 , 5788 , 999 , 1956 , 4072 , 2064 , 3091 , 4288 , 4233 , 4582 , 1000 , 1027 , 7157 , 5111 , 5175 , 5925 , 332 , 1003 , 7431


For Research Use Only. Not For Use In Diagnostic Procedures.
Cell Signaling Technology is a trademark of Cell Signaling Technology, Inc.
PathScan is a trademark of Cell Signaling Technology, Inc.
XP is a registered trademark of Cell Signaling Technology, Inc.
LumiGLO is a registered trademark of Kirkegaard & Perry Laboratories.
U.S. Patent No. 5,675,063.

14821
PathScan® Cancer Phenotype Antibody Array Kit (Chemiluminescent Readout)