View Featured Offers >>
32722
SignalStar™ Fluorescence Removal Kit
Buffers & Dyes
Buffer Kit

SignalStar Fluorescence Removal Kit #32722

Citations (0)
Filter:
  1. IHC
SignalStar multiplex immunohistochemical analysis of paraffin-embedded human gastric adenocarcinoma using CD68 (D4B9C) & CO-0007-488 SignalStar Oligo-Antibody Pair #73071 (green), PD-1 (Intracellular Domain) (D4W2J) & CO-0008-594 SignalStar Oligo-Antibody Pair #35347 (yellow), PD-L1 (E1L3N®) & CO-0005-647 SignalStar Oligo-Antibody Pair #52085 (red), CD3ε (D7A6E) & CO-0001-750 SignalStar Oligo-Antibody Pair #51754 (cyan), and DAPI #4083 (blue) in Imaging Round 1 (left). Following Imaging Round 1, SignalStar oligonucleotides and fluorophores were removed, and the tissue was imaged again using DAPI #4083 (middle, blue). Subsequently, a second round of SignalStar multiplex immunohistochemical analysis was performed using Pan-Keratin (C11) & CO-0003-488 SignalStar Oligo-Antibody Pair #63566 (green), Granzyme B (D6E9W) & CO-0009-594 SignalStar Oligo-Antibody Pair #15194 (yellow), CD20 (E7B7T) & CO-0011-647 SignalStar Oligo-Antibody Pair #36775 (red), CD8α (D8A8Y) & CO-0004-750 SignalStar Oligo-Antibody Pair #62750 (cyan), and DAPI #4083 (blue) in Imaging Round 2 (right). All fluorophores have been assigned a pseudocolor, as indicated. Staining was performed on the BOND RX autostainer by Leica Biosystems.
To Purchase # 32722
Cat. # Size Qty. Price
32722S
1 Kit  (10 slides)

Product Includes Volume
10X dsDNase Buffer 370 µl
dsDNase 37 µl

Product Description

SignalStar multiplex immunohistochemistry (IHC) is an advanced technology for labeling multiple proteins simultaneously in tissue samples using specific primary antibodies and fluorescent detection reagents. This technology offers accuracy and reliability in visualizing and analyzing protein expression while maintaining spatial context and tissue architecture.

The SignalStar Fluorescence Removal Kit is compatible with SignalStar Oligo-Antibody Pairs, SignalStar Midplex IHC Buffer Kit #29414, and SignalStar Miniplex IHC Buffer Kit #63043 for use in fluorescent multiplex imaging experiments. This product is required to remove fluorescent oligos following the final round of signal amplification and imaging of SignalStar Oligo-Antibody Pairs. This buffer kit includes the reagents required for 10 slides. SignalStar Multiplex IHC Kits & Reagents are not compatible with all of Cell Signaling Technology® products and protocols that are recommended for use in immunohistochemical assays.

Product Usage Information

The SignalStar Fluorescence Removal Kit is intended for use following the SignalStar Multiplex IHC Assay Manual protocol or the SignalStar Multiplex IHC Assay for Use on BOND RX Fully Automated Research Stainer by Leica Biosystems protocol. Continue to follow all guidance and recommendations from the original protocol when using the SignalStar Fluorescence Removal Kit.

For the SignalStar Multiplex IHC Assay Manual protocol:

1. After the second round of image acquisition, soak slides in dH2O for >30 min to gently remove coverslip.

2. Combine reagents to create the SignalStar Fluorescence Removal Solution:

a. For 5 slides: 75 µL 10X dsDNase Buffer, 7.5 µL dsDNase, and 667.5 µL Nuclease-free Water #12931.

b. For 10 slides: 150 µL 10X dsDNase Buffer, 15 µL dsDNase, and 1,335 µL Nuclease-free Water #12931.

3. Cover with parafilm and vortex for 10 sec. Store all SignalStar kit components on ice when preparing solutions. SignalStar solutions should be used promptly once all reagents have been combined for the run.

4. Incubate slides in 150 µL of SignalStar Fluorescence Removal Solution for 2 hr at 37°C. (Use of a covered humidity chamber is highly recommended to prevent evaporation.)

5. Immerse slides in dH2O for 30 sec.

6. Complete any additional staining and imaging steps following your manufacturer’s protocol.

For the SignalStar Multiplex IHC Assay for Use on BOND RX Fully Automated Research Stainer by Leica Biosystems protocol:

1. In the BOND RX software by Leica Biosystems, create a copy of the "CST SignalStar Imaging Round 2” protocol.

2. Change the name of the copy to "CST SignalStar Imaging Round 3” with the abbreviated name "CST Rd3.”

3. Select "Show wash steps."

4. Delete Steps 8-63, saving only steps 1-7 for fluorescence removal.

5. Add steps required for any additional staining following your manufacturer’s protocol.

6. Select "CST SignalStar" as the preferred Detection System (Note: Additional staining steps may require further selection of other Detection Systems. Please contact Leica Biosystems for assistance.)

7. Select "Create Protocol.”

8. Click the Save button and then the Yes button to acknowledge the caution message.

9. After the second round of image acquisition, soak slides in dH2O for >30 min to gently remove coverslip.

10. Combine reagents to create the SignalStar Fluorescence Removal Solution:

a. For 5 slides: 185 µL 10X dsDNase Buffer, 18.5 µL dsDNase, and 1,646.5 µL Nuclease-free Water #12931 in 1 BOND Titration Insert.

b. For 10 slides: 335 µL 10X dsDNase Buffer, 33.5 µl dsDNase, and 2,981.5 µL Nuclease-free Water #12931 in 1 BOND Titration Insert.

11. Cover with parafilm and vortex for 10 sec. Store all SignalStar kit components on ice when preparing solutions. SignalStar solutions should be used promptly once all reagents have been combined for the run.

12. In the BOND RX software, create a study and add slides.

13. When "adding slides," use the selections below for Tissue Preparation on BOND:

a. Slide preparation: -- (no value/not required)

b. Dispense Volume: 150 µL

c. HIER: -- (no value/not required)

14. Select "CST SignalStar Imaging Round 3," ensuring that Slide preparation is selected as "--" and HIER is selected as "--."

15. Print labels, add labels to slides, and place slides onto the slide tray.

16. Place 2-3 drops of dH2O onto each slide before adding BOND covertiles.

17. Start the BOND RX run.

Storage

All components in this kit are stable for at least 12 months when stored at the recommended temperature.

Limited Uses

Except as otherwise expressly agreed in a writing signed by a legally authorized representative of CST, the following terms apply to Products provided by CST, its affiliates or its distributors. Any Customer's terms and conditions that are in addition to, or different from, those contained herein, unless separately accepted in writing by a legally authorized representative of CST, are rejected and are of no force or effect.

Products are labeled with For Research Use Only or a similar labeling statement and have not been approved, cleared, or licensed by the FDA or other regulatory foreign or domestic entity, for any purpose. Customer shall not use any Product for any diagnostic or therapeutic purpose, or otherwise in any manner that conflicts with its labeling statement. Products sold or licensed by CST are provided for Customer as the end-user and solely for research and development uses. Any use of Product for diagnostic, prophylactic or therapeutic purposes, or any purchase of Product for resale (alone or as a component) or other commercial purpose, requires a separate license from CST. Customer shall (a) not sell, license, loan, donate or otherwise transfer or make available any Product to any third party, whether alone or in combination with other materials, or use the Products to manufacture any commercial products, (b) not copy, modify, reverse engineer, decompile, disassemble or otherwise attempt to discover the underlying structure or technology of the Products, or use the Products for the purpose of developing any products or services that would compete with CST products or services, (c) not alter or remove from the Products any trademarks, trade names, logos, patent or copyright notices or markings, (d) use the Products solely in accordance with CST Product Terms of Sale and any applicable documentation, and (e) comply with any license, terms of service or similar agreement with respect to any third party products or services used by Customer in connection with the Products.

For Research Use Only. Not for Use in Diagnostic Procedures.
Cell Signaling Technology is a trademark of Cell Signaling Technology, Inc.
SignalStar is a trademark of Cell Signaling Technology, Inc.
U.S. Patent No. 10,781,477, foreign equivalents, and child patents deriving therefrom.
All other trademarks are the property of their respective owners. Visit our Trademark Information page.