Cat. # | Size | Qty. | Price |
---|---|---|---|
29580S | 1 Kit (24 assays) |
|
$ 201 |
Product Includes | Volume (with Count) | Storage Temp | |||
---|---|---|---|---|---|
Adaptor for Illumina® | 1 x 240 µl | -20°C | |||
USER® Enzyme | 1 x 72 µl | -20°C | |||
Universal PCR Primer for Illumina® | 1 x 120 µl | -20°C | |||
Index 1 Primer for Illumina® | 1 x 10 µl | -20°C | |||
Index 2 Primer for Illumina® | 1 x 10 µl | -20°C | |||
Index 3 Primer for Illumina® | 1 x 10 µl | -20°C | |||
Index 4 Primer for Illumina® | 1 x 10 µl | -20°C | |||
Index 5 Primer for Illumina® | 1 x 10 µl | -20°C | |||
Index 6 Primer for Illumina® | 1 x 10 µl | -20°C | |||
Index 7 Primer for Illumina® | 1 x 10 µl | -20°C | |||
Index 8 Primer for Illumina® | 1 x 10 µl | -20°C | |||
Index 9 Primer for Illumina® | 1 x 10 µl | -20°C | |||
Index 10 Primer for Illumina® | 1 x 10 µl | -20°C | |||
Index 11 Primer for Illumina® | 1 x 10 µl | -20°C | |||
Index 12 Primer for Illumina® | 1 x 10 µl | -20°C |
Product Information
Store all components at -20ºC. This product is stable for 12 months if stored properly.
Next generation sequencing (NG-seq) is a high throughput method that can be used downstream of chromatin immunoprecipitation (ChIP) and Cleavage Under Targets and Release Using Nuclease (CUT&RUN) assays to identify and quantify target DNA enrichment across the entire genome. Multiplex Oligos for Illumina® (Single Index Primers) (ChIP-seq, CUT&RUN) contain adaptors and primers that are ideally suited for multiplex sample preparation for NG-seq on the Illumina® platform (Illumina, Inc.). This kit can be used to generate up to 12 distinct, barcoded ChIP-seq or CUT&RUN DNA libraries that can be combined into a single sequencing reaction.
Each kit component must pass rigorous quality control standards, and for each new lot the entire set of reagents is functionally validated together by construction and sequencing of indexed libraries on the Illumina® sequencing platform.
This product provides enough reagents to support up to 24 DNA sequencing libraries, and must be used in combination with the DNA Library Prep Kit for Illumina® (ChIP-seq, CUT&RUN) #56795.
Compatible Assay kits:
SimpleChIP® Enzymatic Chromatin IP Kit (Magnetic Beads) #9003
SimpleChIP® Plus Enzymatic Chromatin IP Kit (Magnetic Beads) #9005
SimpleChIP® Plus Sonication Chromatin IP Kit #56383
DNA Library Prep Kit for Illumina® (ChIP-seq, CUT&RUN) #56795
CUT&RUN Assay Kit #86652
Non-Compatible SimpleChIP® kits:
SimpleChIP® Enzymatic Chromatin IP Kit (Agarose Beads) #9002
SimpleChIP® Plus Enzymatic Chromatin IP Kit (Agarose Beads) #9004
Note: Agarose beads are blocked with sonicated salmon sperm DNA, which will contaminate DNA library preps and NG-seq.
Required Reagents:
Reagents Included:
Reagents Not Included:
Illumina® NG-seq platforms use a red laser/LED to sequence A/C and a green laser/LED to sequence G/T. For each cycle, both the red and the green channel need to be read to ensure proper image registration (i.e. A or C must be present in each cycle, and G or T must be present in each cycle). If this color balance is not maintained, sequencing the index read could fail. Please check the sequences of each index to be used to ensure that you will have signal in both the red and green channels for every cycle. See example below:
The following table lists some (but not all) valid index combinations that can be sequenced together:
Multiplex Oligos for Illumina® (Single Index Primers) (ChIP-seq, CUT&RUN) can generate 12 different, barcoded samples if each Index primer is used only once with Universal PCR Primer for Illumina®. Each Index Primer is supplied in sufficient amounts to generate two libraries, but these two libraries cannot be pooled together in one sequencing lane.
For 1-plex (no pooling), use any index primer with the universal PCR primer.
Each Index Primer for Illumina® is provided in volume of 10 µl.
Where -s- indicates phosphorothioate bond.
The components in the SimpleChIP® ChIP-seq Multiplex Oligos for Illumina® (Single Index Primers) #29580 are individually validated by the functional testing listed below and must pass rigorous quality control standards. Furthermore, each set of components is functionally validated together by construction and sequencing of indexed libraries on the Illumina® sequencing platform.
5´-/5Phos/GAT CGG AAG AGC ACA CGT CTG AAC TCC AGT C/ideoxyU/A CAC TCT TTC CCT ACA CGA CGC TCT TCC GAT C-s-T-3´
Quality Control Assays
Supplied in: 50 mM KCl, 5 mM NaCl, 10 mM Tris-HCl (pH 7.4 @ 25°C), 0.1 mM EDTA, 1 mM DTT, 175 μg/ml BSA and 50% Glycerol
Quality Control Assays
5´-AAT GAT ACG GCG ACC ACC GAG ATC TAC ACT CTT TCC CTA CAC GAC GCT CTT CCG ATC*T-3´
Quality Control Assays
Quality Control Assays
posted November 2017
revised April 2022
protocol id: 1626
Protocol Id: 1626
Protocol Id:
Except as otherwise expressly agreed in a writing signed by a legally authorized representative of CST, the following terms apply to Products provided by CST, its affiliates or its distributors. Any Customer's terms and conditions that are in addition to, or different from, those contained herein, unless separately accepted in writing by a legally authorized representative of CST, are rejected and are of no force or effect.
Products are labeled with For Research Use Only or a similar labeling statement and have not been approved, cleared, or licensed by the FDA or other regulatory foreign or domestic entity, for any purpose. Customer shall not use any Product for any diagnostic or therapeutic purpose, or otherwise in any manner that conflicts with its labeling statement. Products sold or licensed by CST are provided for Customer as the end-user and solely for research and development uses. Any use of Product for diagnostic, prophylactic or therapeutic purposes, or any purchase of Product for resale (alone or as a component) or other commercial purpose, requires a separate license from CST. Customer shall (a) not sell, license, loan, donate or otherwise transfer or make available any Product to any third party, whether alone or in combination with other materials, or use the Products to manufacture any commercial products, (b) not copy, modify, reverse engineer, decompile, disassemble or otherwise attempt to discover the underlying structure or technology of the Products, or use the Products for the purpose of developing any products or services that would compete with CST products or services, (c) not alter or remove from the Products any trademarks, trade names, logos, patent or copyright notices or markings, (d) use the Products solely in accordance with CST Product Terms of Sale and any applicable documentation, and (e) comply with any license, terms of service or similar agreement with respect to any third party products or services used by Customer in connection with the Products.