< Back to Support Article Search Results
The kits may require additional optimization with starting dilutions. We recommend running a titration curve starting with neat samples to determine the optimal loading concentration.
Can we use your ELISA Kit with cerebrospinal fluid (CSF) samples?
Although we have not tested every ELISA target with cerebrospinal fluid (CSF), we have tested several of our β-amyloid and tau targets with both normal and Alzheimer's disease (AD) human CSF samples.
The kits tested include:
- FastScan™ β-Amyloid (1-40) ELISA Kit #20882
- PathScan® RP β-Amyloid (1-42) Sandwich ELISA Kit #27029
- FastScan™ Phospho-Tau (Thr181) ELISA Kit #58537
- PathScan® RP Phospho-Tau (Thr217) Sandwich ELISA Kit #59672
The kits may require additional optimization with starting dilutions. We recommend running a titration curve starting with neat samples to determine the optimal loading concentration.
Last updated: October 8, 2024