Basket Updated

0

Items added

1% for the planet logo
< Back to Support Article Search Results

What is the depth of sequencing reads per sample required in a CUT&RUN assay?

We suggest a sequencing depth of 3-5 million reads per sample. Because of the very low background signal generated in CUT&RUN, this sequencing depth is usually sufficient for histone modifications and transcription factors. We have found that less than 3 million does not work and greater than 15 million greatly increases the number of duplicate reads.

Last updated: February 27, 2024

Was this article helpful?

Technical Support

Email: [email protected]

Send Us a Message

Call: 877-678-8324

Customer Support

Email: [email protected]

Send Us a Message

Call: 877-616-2355

Fax: 866-432-6112

Contact Sales

Email: [email protected]

Send Us a Message

Call: 877-616-2355